If you still have problems, please let us know, by sending an email to support@website.com . Thank you!
Showing 1–9 of 13 results
Features: ⊙TC/RTD/Analog Signal Universal Input; ⊙Multi Display Units can be choosed; ⊙With Display, Alarm and Current Transmit function; ⊙With RS485 Communication Function; ⊙Power Supply: 100–240VAC
Input signal mA, V, mV and RTD selected by software; measuring range/Zero point can be adjusted.Two loops of relay alarm output. Capacity 250VAC/3A or 30VDC/5A.4-20mA analogue output.Auxiliary output power supply 24V/12V/30mA.W/ RS485 communication terminal.Accuracy: ¡À0.3% FS.Applied for 2-loop transformer, pressure sensor, 4-loop weighing sensor, distance pressure meter, etc.
Driven with excellence, we are presenting PID Temperature Controller to our customers.
Autonics Standard Type PID Temperature Controller. It supports heating/cooling simultaneous control, automatic/manual control, SSR output/current output selectable function, SSRP output function and communication function. In addition, it covers diverse input sensor support, multi SV setting, high resolution display part and compact size. The offered controllers are manufactured by making use of high grade basic materials and leading technology in synchronization with the set industrial norms.
Multi functional display, with integrated loop power supply, for monitoring and displaying analogue process measurements.
Multi functional 1 channel display with universal input, loop power supply, limit monitor and analogue output
The process meter monitors and displays the analog measured values. Pumps can be monitored with the digital status inputs. The RIA452 can provide power directly to two-wire sensors connected. Up to eight freely programmable relays monitor the measured value. Other operating modes for the relays include sensor or device malfunction, batch and pump control functions. Furthermore, the RIA452 can be used as a preset counter and for measuring flow at open channels and measuring weirs.
X96 is a full-featured PID controller. It receives 2 universal inputs which can be factory-programmed for either of two groups. Group 1 contains 8 types of thermocouples (B, E, J, K, N, R, S, T), Pt100 RTDs and 0/4-20 mA and 0-50 mV linear inputs. Group 2 contains 11 types of thermocouples (B, C, D, E, G, J, K, N, R, S, T), Pt100 and Cu53 RTDs, 0/4-20 mA and 0-50 mV linear inputs. A large LED dual-display on the front of the process controller shows the difference in values of the setpoint and process value while 11 additional LEDs indicate the state of each of the 4 relays, 4 setpoints, Auto/Manual and communication status. Buttons on the front of X96 allow operators to easily set up to 5 setpoints – 4 for the relays as well as one for a 4 – 20 mA signal should they choose to use the linear output for control. With an error of only 0.1% of the full-scale, this is a process controller of superior accuracy.